BDRZV - HC-433, VV-L-800A

Product Identification

Product ID:HC-433, VV-L-800A
MSDS Date:01/01/1985
FSC:9150
NIIN:00-273-2389
MSDS Number: BDRZV

Responsible Party
HANOVER PROCESSING COMPANY

Emergency Phone: 201-386-0009

Cage: 3P444

Contractor
HANOVER PROCESSING CO INC DIV OF ROYAL LUBRICANTS
EAST HANOVER, NJ 07936 US

Telephone: 201-887-7410

Cage: 3P444

Ingredients

PETROLEUM OIL,REFINED

Fraction By Weight: >90%


BARIUM PETROLEUM SULFONATE

Fraction By Weight: <5%


ANTI OXIDANTS DI-T-BUTYL-P-CRESOL

Fraction By Weight: <1%

Hazards

Effects of Overexposure:ORAL: SLIGHTLY TOXIC. MILK SKIN IRRITANT. IRRIT
TO EYES.

First Aid

First Aid:ORAL:DO NOT INDUCE VOMITING. ASPIRATION TREATMENT PROBABLY
NOT REQUIRED. CONSULT MD. EYES:FLUSH W/ COPIOUS QTY OF WATER.

Fire Fighting

Flash Point:300F COC
Extinguishing Media:CO*2 OR DRY CHEMICAL
Fire Fighting Procedures:THIS PRODUCT FLOATS ON WATER, SO WATER MAY
SPREAD FIRE
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:ABSORB W/ CLAY, DIATOMACEOUS EARTH OR OTHER
INERT ABSORBANT

Handling

Handling and Storage Precautions:NO EXTRA PRECAUTIONS NEEDED HOWEVER,
AVOID BREATHING OF OIL MIST. DO NOT HANDLE FOODS UNTIL HANDS ARE
WASHED W/ SOAP & WATER.

Exposure Controls

Respiratory Protection:NOT NORMALLY REQUIRED (MFR)
Ventilation:LOC EXHST AS REQUIRED IF MIST IS BEING GENERATED
Protective Gloves:NOT NORM REQD
Eye Protection:GOGGLES IF MIST OR SPLASH
Other Protective Equipment:NOT REQUIRED
Supplemental Safety and Health
MFR STATES PRODUCT CONTAINS NO BENZENE; DOES NOT CONTAIN ANY MATERIALS
LISTED ON OSHA TABLES Z-1,Z-2,Z-3. VAPOR PRESSURE: NIL.VAPOR
DENSITY: NIL. % VOLATILE BY VOL: NIL.

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:>400F
Spec Gravity:0.8827
Evaporation Rate & Reference:NIL
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER COLOR -SLIGHT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
LIQUID OXYGEN
Hazardous Decomposition Products:CARBON MONOXIDE - COULD FORM DURING
COMBUSTION

Disposal

Waste Disposal Methods:MFR RECM CONTROL BURNING. DISPOSE IAW FED, STATE
& LOCAL CODES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.